期刊名称:Pertanika Journal of Social Sciences & Humanities
印刷版ISSN:0128-7702
电子版ISSN:2231-8534
出版年度:1985
卷号:8
期号:1
出版社:Universiti Putra Malaysia
摘要:Measurements have been made of the temperature profile along the stainless steel neck of a 25litre commercial dewar fo r the storage of liquid nitrogen. The temperature profile of the boundarylayer of the effluent gas was also measured. The major heat inleak into the liquid nitrogen bath is due to the solid heat conduction down the neck wall and to the vapour recirculation process. These two sources contributed about 80% of the total heat inleak. The solid heat conduction was due to the fact that the neck was short and as such the refrigerative value of the cold effluent gas was not fully utilised. The vapour recirculation process is due to the reverse mass flux of the warmer gas into the bath.