摘要:To improve performance and design of the cryogenic pump, analyze and solve the pump fault, and ensure the reliability of design and operating, it is highly necessary to understand the cryogenic pump temperature profile. Regarding horizontal single cryogenic centrifugal pump as the studied object, the flow field and structural heat transfer is calculated and analyzed. Based on reasonable boundary condition, three dimensional steady state of the pump mesh model is calculated by finite-element method with the software of Fluent, the fluid pressure field and the whole structural temperature profile is obtained. The structural temperature profile by finite-element heat transfer calculation indicates that: in the operating range of the cryogenic pump, the pumping cryogenic liquid is unable to vaporize at the room temperature, and the low temperature area is unable to interfere with the gear case in normal operation.