  • 标题:Obstruction of an Endotracheal Tube with Change of the Head Position in a Trachea Deviated Patient - A case report -
  • 本地全文:下载
  • 作者:Han, Dong Woo ; Chang, Chul Ho ; Lee, Jong Seok
  • 期刊名称:Korean Journal of Anesthesiology
  • 印刷版ISSN:2005-6419
  • 出版年度:2007
  • 卷号:52
  • 期号:3
  • 页码:339-341
  • DOI:10.4097/kjae.2007.52.3.339
  • 语种:Korean
  • 出版社:The Korean Society of Anesthesiologists,
  • 摘要:

    Various causes of endotracheal tube obstruction during general anesthesia exist. Herein, the case of a 77-year old male patient, with tracheal deviation, who was intubated with an endotracheal tube in the emergency room, without a Murphy eye, is reported. He was transferred to the operating room for the removal of a subdural hematoma. The endotracheal tube suddenly became obstructed during flexion of neck for the craniotomy procedure. The distal bevel of the endotracheal tube, without Murphy eye, was discovered to have come into contact with the tracheal wall, with the airway being obstructed during the fiberoptic bronchoscopy. Shortly after extubation of the obstructed tube, an armored tube, with a Murphy eye, was reintubated, after which the respiration pattern immediately returned to normal.

  • 关键词:endotracheal tube obstruction; Murphy eye; tracheal deviation