Tension pneumothorax during ventilating bronchoscopy for foreign body removal is a rare but life-threatening complication. The authors present a case of cardiac arrest caused by tension pneumothorax in a 9-month-old girl who underwent ventilating bronchoscopy for foreign body (peanut) removal. Tension pneumothorax was due to tracheobronchial lacerations caused by a bronchoscope. The patient was successfully resuscitated by cardiopulmonary resuscitation and chest tube insertion. The airway injury was effectively repaired by thoracotomy under extracorporeal membrane oxygenation.