首页    期刊浏览 2024年07月08日 星期一
登录注册

文章基本信息

  • 标题:Comparison of Frequency Doubling Technology Perimeter and RNFL Photography for Early Diagnosis of Glaucoma
  • 本地全文:下载
  • 作者:Lee, Jun Sung ; Heo, Hwan ; Park, Sang Woo
  • 期刊名称:Journal of the Korean Ophthalmological Society
  • 印刷版ISSN:0378-6471
  • 出版年度:2009
  • 卷号:50
  • 期号:11
  • 页码:1674-1679
  • DOI:10.3341/jkos.2009.50.11.1674
  • 语种:Korean
  • 出版社:The Korean Ophthalmological Society
  • 摘要:Purpose

    To compare the frequency doubling technology perimeter (FDT) with retinal nerve fiber layer (RNFL) photography as a tool for the early detection of glaucoma.

    Methods

    Ninety-eight eyes of 98 patients were evaluated over a period of 3 months. According to the results of RNFL photography and FDT, Patients were divided into four groups based on the results of RNFL photography and optical coherence tomography (OCT). A comparison of the RNFL thickness of each group was performed using the OCT results.

    Results

    RNFL thickness in the group with abnormal FDT and normal RNFL were significantly decreased from those in the group with normal FDT and RNFL photography at the 6, 7 and, 10 o'clock area ( p <0.05).

    Conclusions

    There were statistically significant differences in the RNFL thickness between the group with abnormal FDT and normal RNFL photography, and the group with normal FDT and RNFL photography within the limited areas. These results imply that FDT is more useful for the early detection of glaucoma than RNFL photography.

  • 关键词:FDT; Glaucoma; RNFL photography; Stratus OCT