首页    期刊浏览 2024年09月18日 星期三
登录注册

文章基本信息

  • 标题:Visual Outcome and Patient Satisfaction after Implantation of Multifocal IOLs: Three-Month Follow-Up Results
  • 本地全文:下载
  • 作者:Kim, Sung Min ; Kim, Chi Hoon ; Chung, Eui-Sang
  • 期刊名称:Journal of the Korean Ophthalmological Society
  • 印刷版ISSN:0378-6471
  • 出版年度:2012
  • 卷号:53
  • 期号:2
  • 页码:230-237
  • DOI:10.3341/jkos.2012.53.2.230
  • 语种:Korean
  • 出版社:The Korean Ophthalmological Society
  • 摘要:Purpose

    To evaluate the visual outcome and patient satisfaction at three months after implantation of ReSTOR® Aspheric multifocal IOL D1 (+3.0 D) and D3 (+4.0 D) in unilateral and bilateral cataract surgery groups.

    Methods

    Among 73 patients who received cataract surgery and implantation of D1 or D3, visual outcome and satisfaction score of 34 patients in the unilateral surgery group and 39 patients in the bilateral surgery group were analyzed respectively. The unilateral surgery group was divided into 2 sub-groups (D1, D3), and the bilateral surgery group was sub-divided into 3 groups (D1/D1, D1/D3, D3/D3) according to the combination of implanted IOL. Uncorrected near visual acuity (UNVA, 30 cm), uncorrected intermediate visual acuity (UIVA, 40 cm, 50 cm), uncorrected distant visual acuity (UDVA) and best corrected visual acuity (BDVA) were measured at three months postoperatively. Also, all patients answered questionnaires to assess satisfaction.

    Results

    In the unilateral surgery sub-groups, visual acuity of the D1 group was higher than that of the D3 group at 50 cm ( p < 0.001), although the D3 group showed better visual outcome at 30 cm ( p < 0.001). In satisfaction analysis, the D1 group reported significantly higher scores in three categories (general satisfaction with surgery; p = 0.027, intermediate vision; p < 0.001, recommendation to others; p = 0.026). Among the bilateral surgery groups, the D1/D1 group showed the best intermediate visual acuity at 50 cm ( p = 0.011), and the D3/D3 group achieved the highest postoperative near visual acuity ( p = 0.004). In satisfaction analysis, the scores of the three categories (general satisfaction with surgery; p = 0.008, intermediate vision; p < 0.001, recommendation to others; p = 0.006) showed significant differences among the three groups, with the D1/D1 group reporting the highest scores in all three categories.

    Conclusions

    In bilateral ReSTOR® lens implantation, insertion of D1 in both eyes is expected to achieve the most favorable visual outcome and patient satisfaction. In unilateral ReSTOR® lens implantation, implantation of D1 rather than D3 would be more advantageous in general.

  • 关键词:Multifocal IOL; ReSTOR D1; ReSTOR D3; Satisfaction
国家哲学社会科学文献中心版权所有