首页    期刊浏览 2024年11月30日 星期六
登录注册

文章基本信息

  • 标题:The Relationship among Refractive Power, Axial Length and Choroidal Thickness Measured by SD-OCT in Myopia
  • 本地全文:下载
  • 作者:Kim, Keun Ho ; Kim, Do Gyun
  • 期刊名称:Journal of the Korean Ophthalmological Society
  • 印刷版ISSN:0378-6471
  • 出版年度:2012
  • 卷号:53
  • 期号:5
  • 页码:626-631
  • DOI:10.3341/jkos.2012.53.5.626
  • 语种:Korean
  • 出版社:The Korean Ophthalmological Society
  • 摘要:Purpose

    To measure choroidal thickness in healthy myopic eyes and to evaluate the relationship among choroidal thickness and refractive power and axial length.

    Methods

    Eighty healthy myopic eyes were evaluated in the present study. The refractive power was measured using an automatic refractor and the axial length using A-scan. The subjects were divided into two groups based on refractive power (≥-6.0 D and <-6.0 D) and axial length (≥25 mm and <25 mm). The choroidal thickness was measured using spectral domain (SD) optical coherence tomography (3-dimensional [3D] OCT-2000, Software Version 6.01; Topcon Corp., Tokyo, Japan), and the statistical relationship between the two groups was analyzed.

    Results

    A statistically significant difference was found in choroidal thickness according to refractive power and axial length between the two groups ( p < 0.001 and p < 0.05, respectively).

    Conclusions

    Refractive power and axial length had a significant relation to choroidal thickness measured by OCT. When excluding eyes with pathologic myopia, high myopia in healthy eyes may cause choroidal thinning.

  • 关键词:Axial length; Choroidal thickness; Optical coherence tomography; Refractive power