  • 标题:Comparison of Six-Month Outcomes in Eyes with Two Hydrophilic Aspheric Intraocular Lenses after Cataract Surgery
  • 本地全文:下载
  • 作者:Um, Taewoong ; Lee, Joo Eun ; Kim, Jae Hyung
  • 期刊名称:Journal of the Korean Ophthalmological Society
  • 印刷版ISSN:0378-6471
  • 出版年度:2012
  • 卷号:53
  • 期号:6
  • 页码:767-774
  • DOI:10.3341/jkos.2012.53.6.767
  • 语种:Korean
  • 出版社:The Korean Ophthalmological Society
  • 摘要:Purpose

    To compare the six-month clinical outcomes of Tek-Lens II model 872 (Tekia, Inc.) and Akreos MI-60 (Bausch & Lomb, Inc.) hydrophilic aspheric intraocular lenses (IOLs) implanted in-the-bag.

    Methods

    After phacoemulsification was performed by a single surgeon (JY Kim), two different hydrophilic aspheric IOLs were implanted: the Tek-Lens II IOL in 57 eyes and the MI60 IOL in 49 eyes. The best corrected visual acuity (BCVA), refractive error (RE), total high-order aberration (HOA), anterior chamber depth (ACD), and contrast sensitivity (CS) were measured preoperatively and one, three, and six months postoperatively. All parameters were analyzed using the independent t -test to compare the two IOL groups.

    Results

    There was no significant difference in the BCVA, RE, or HOA between the two groups at any of the follow-up visits. Three months postoperatively, the ACD of the TEK-Lens II group as measured by corneal topography was significantly shallower than that of the MI60 group (3.67 ± 0.52 mm vs. 4.10 ± 0.40 mm; p = 0.008), and most of the photopic CS in the Tek-Lens II group was significantly higher than that in the MI60 group (all p < 0.05).

    Conclusions

    The Tek-Lens II IOL showed comparable clinical outcomes with a proven hydrophilic aspheric IOL for the postoperative six months.

  • 关键词:Aspheric intraocular lens; Hydrophilic intraocular lens; Tek-Lens II model 872™