  • 标题:Comparison of Anterior Chamber Parameter and Refractive Change between Three-Piece and Single-Piece Aspheric Intraocular Lenses
  • 本地全文:下载
  • 作者:Kim, Hye Sun ; Lee, Dong Min ; Ahn, Ji Min
  • 期刊名称:Journal of the Korean Ophthalmological Society
  • 印刷版ISSN:0378-6471
  • 出版年度:2012
  • 卷号:53
  • 期号:12
  • 页码:1789-1793
  • DOI:10.3341/jkos.2012.53.12.1789
  • 语种:Korean
  • 出版社:The Korean Ophthalmological Society
  • 摘要:Purpose

    To compare the anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA) and refractive change after cataract surgery between 3-piece and 1-piece aspheric intraocular lens (IOL) implantation.

    Methods

    The present study consisted of 16 patients (25 eyes) having 3-piece aspheric Tecnis® ZA9003 IOL and 21 patients (30 eyes) having 1-piece aspheric Tecnis® ZCB00 IOL. The ACD, ACV, and ACA were measured using an anterior eye segment analysis system (Pentacam, Oculus, Wetzlar, Germany) preoperatively and postoperatively 1 week and 1 month. Refractive outcomes were evaluated using an autokeratometer.

    Results

    When comparing the 3-piece (Tecnis® ZA9003) and 1-piece (Tecnis® ZCB00) IOL with the same optic, ACD, ACV, and AVA increased significantly after cataract surgery. The 1-piece IOL showed deeper ACD than the 3-piece IOL at postoperative 1 week and 1 month. Postoperative refraction showed slight myopic shift compared with target diopter, but was stable in both groups.

    Conclusions

    There was significant increase in ACD, ACV, and ACA after cataract surgery in both IOL-inserted groups. Results showed stable refraction after cataract surgery in both groups. Consideration of the A-constant will be needed because of myopic change with the 1-piece IOL.

  • 关键词:Anterior chamber depth; Aspheric IOL; Refraction; Tecnis® ZA9003; Tecnis® ZCB00