To evaluate the change in multifocal visual evoked potential (mfVEP) in unilateral anisometropic amblyopia before and after occlusion treatment.
MethodsThe mfVEP was performed using RETIscan® (Roland,Brandenburg, Germany) for patients with unilateral anisometropic amblyopia before and after occlusion treatment. Amplitude and latency values of mfVEP were analyzed according to the field divided by 6 rings or 4 sectors.
ResultsThe each amplitude of values of all 6 rings were not significantly different before treatment ( p = 0.077) in amblyopic eyes. However, the value of ring 1 ( p = 0.00) was significantly higher than the value of other rings after treatment. In fellow eyes, the values of ring 1 was consistently significantly higher than the value of other rings before ( p = 0.014) and after ( p = 0.049) occlusion treatment. Additionally, the amplitudes of ring 1 ( p = 0.005) and ring 3 ( p = 0.007) were significantly increased in amblyopic eyes after occlusion treatment. In fellow eyes, the values of all rings did not change significantly. The analysis of amplitudes with 4 sectors revealed no significant result. The analysis of latencies with 6 rings and 4 sectors revealed no significant result.
ConclusionsThe change in amplitude on the central field (ring 1) in amblyopic eyes can be a useful objective monitoring method observing the improvement progress in visual acuity.