To compare the clinical 3 months postoperative results of three different 1-piece aspheric intraocular lenses (IOLs): AcrySof IQ SN60WF (Alcon Laboratories, INC, Fort Worth, TX), TECNIS 1-piece ZCB00 (AMO Inc., Santa Ana, CA) and the newly developed enVista MX60 (Bausch & Lomb, Rochester, NY).
MethodsIn a total of 62 eyes, 1 of the 3 1-piece aspheric IOLs, AcrySof IQ SN60WF, TECNIS 1-piece ZCB00 or enVista MX60 was implanted after cataract extraction. Best corrected visual acuity (BCVA), uncorrected visual acuity (UCVA), and spherical equivalent were assessed 3 months postoperatively. Total spherical aberration, high order aberration, and modulation transfer function were analyzed.
ResultsThere were no significant differences of UCVA, BCVA, the accuracy of postoperative refractive power, and modulation transfer function among the 3 IOLs. Higher order aberrations of the entire eye and internal optics showed almost no significant differences.
ConclusionsThe newly developed IOL, enVista MX60, showed equivalent clinical outcomes as both AcrySof IQ SN60WF and TECNIS 1-piece ZCB00.