首页    期刊浏览 2024年11月27日 星期三
登录注册

文章基本信息

  • 标题:Anatomical Location and Distribution of Supraorbital Notch and Foramen Evaluations Using Facial 3D Computed Tomography
  • 本地全文:下载
  • 作者:Choi, Kwang Eon ; Lee, Hwa ; Chang, Min Wook
  • 期刊名称:Journal of the Korean Ophthalmological Society
  • 印刷版ISSN:0378-6471
  • 出版年度:2014
  • 卷号:55
  • 期号:11
  • 页码:1573-1578
  • DOI:10.3341/jkos.2014.55.11.1573
  • 语种:Korean
  • 出版社:The Korean Ophthalmological Society
  • 摘要:Purpose

    To evaluate anatomical locations and distributions of supraorbital notch and foramen using facial 3D computed tomography in the Korean adult population.

    Methods

    The study sample was composed of 87 adult patients with no history of trauma or ocular disease. The horizontal position of the supraorbital foramen or notch was recorded in relation to a vertical line defined by a reproducible hypothetical point, such as the nasion and mid-maxilla and the midpoint of the horizontal supraorbital plane. The distance and angle for each supraorbital foramen and notch were calculated from the defined vertical line. Furthermore, vertical distance from supraorbital plane, which was established using the highest points of both supraorbital rims, was obtained from the supraorbital foramen.

    Results

    The mean age of the 87 patients was 45.44 ± 8.34 years (range, 30-59 years). There were 66 eyes in the supraorbital notch and 108 eyes in the supraorbital foramen. There were no distributional differences between the 2 sides. The mean horizontal distance of both types was 23.95 ± 3.93 mm (range, 16.41-38.94 mm). The horizontal distance of male patients was longer than the female patients (25.18 ± 4.16 mm vs. 22.63 ± 3.19 mm, p < 0.001, based on independent t -test) and the horizontal distance of supraorbital notch was shorter than the supraorbital foramen (22.59 ± 3.18 mm vs. 26.18 ± 4.04 mm, respectively, p < 0.001, based on independent t -test). The mean vertical distance and mean angles of the supraorbital foramen were 3.02 ± 1.119 mm and 6.81 ± 2.31 degrees (°), respectively.

    Conclusions

    The present study described the anatomical location of each supraorbital opening type in Korean adults. According to horizontal distance, a surgeon can avoid iatrogenic injury of the supraorbital neurovascular complex, especially during brow surgery. In addition, the anatomy can aid in targeting supraorbital neurovascular complex in cases of nerve block.

  • 关键词:Supraorbital foramen; Supraorbital notch; Three-demensional computed tomography
国家哲学社会科学文献中心版权所有