首页    期刊浏览 2024年10月06日 星期日
登录注册

文章基本信息

  • 标题:Comparison of Continuous Curvilinear Capsulorhexis Parameters between Femtosecond Laser and Conventional Cataract Surgery
  • 本地全文:下载
  • 作者:Park, Jae Hong ; Lee, Kyung Heon ; Lee, Dong Jun
  • 期刊名称:Journal of the Korean Ophthalmological Society
  • 印刷版ISSN:0378-6471
  • 出版年度:2014
  • 卷号:55
  • 期号:12
  • 页码:1800-1807
  • DOI:10.3341/jkos.2014.55.12.1800
  • 语种:Korean
  • 出版社:The Korean Ophthalmological Society
  • 摘要:Purpose

    To compare parameters of femtosecond laser and manual continuous curvilinear capsulorhexis (CCC) using anterior segment optical coherence tomography (AS-OCT).

    Methods

    Femtosecond laser cataract surgery was performed in 30 eyes of 30 patients, and conventional cataract surgery with a manual CCC in 30 eyes of 30 patients. One month after surgery, CCC diameters, circularity of capsulotomy, and distance between the CCC and pupil center were analyzed using the AS-OCT.

    Results

    Mean maximal CCC diameter was 4.96 ± 0.23 mm in the femtosecond laser group, and 4.70 ± 0.82 mm in the manual CCC group. Mean minimal CCC diameter was 4.91 ± 0.23 mm in the femtosecond group, and 4.48 ± 0.64 mm in the manual CCC group showing significant difference between the two groups ( p = 0.000). Circularity of capsulotomy was 0.99 ± 0.01 in the femtosecond group and 0.91 ± 0.13 in the manual CCC group and was statistically different between the 2 groups ( p = 0.000). The distance from the CCC center to the pupil center was 0.18 ± 0.09 mm in the femtosecond group and 0.26 ± 0.17 mm in the manual CCC group. The CCC center was closer to the pupil center in the femtosecond than in the manual CCC group ( p = 0.038).

    Conclusions

    Properly sized and shaped capsulotomy can be expected in femtosecond laser CCC compared with manual CCC.

  • 关键词:Capsulotomy; Circularity; Femtosecond cataract surgery