首页    期刊浏览 2024年11月24日 星期日
登录注册

文章基本信息

  • 标题:Treatment of Femur Supracondylar Fracture with Locking Compression Plate
  • 本地全文:下载
  • 作者:Bae, Seong Ho ; Cha, Seung Han ; Suh, Jeung Tak
  • 期刊名称:Journal of the Korean Fracture Society
  • 印刷版ISSN:1225-1682
  • 出版年度:2010
  • 卷号:23
  • 期号:3
  • 页码:282-288
  • DOI:10.12671/jkfs.2010.23.3.282
  • 语种:Korean
  • 出版社:The Korean Fracture Society
  • 摘要:Purpose

    To evaluate the effectiveness of locking compression plate by analyzing the clinical outcomes of open reduction and internal fixation with locking compression plate in the treatment of femur supracondylar fracture.

    Materials and Methods

    We reviewed 21 cases of distal femur fractures which were treated with locking compression plate in our hospital from February 2005 to March 2009 and followed up for minimal 1 year. The types of fractures were seven A1, four A2, two A3, six C2, and two C3 according to AO classification. 2 cases were open fractures. The cases were evaluated by the criteria of Schatzker-Lambert.

    Results

    The mean time to union was 14.3 weeks. One delayed union, one refracture were observed, but no nonunion and postoperative infection was observed. The outcomes were excellent in 6 cases, good in 11, fair in 3, and failure in 1 by the criteria of Schatzker-Lambert. The overall results were excellent or good in 17 cases (81.0%).

    Conclusion

    In the treatment of femur supracondylar fracture, open reduction and internal fixation with locking compression plate yields good result and locking compression plate is useful choice of fixation option.

  • 关键词:Femur; Supracondylar fracture; Locking compression plate
国家哲学社会科学文献中心版权所有