首页    期刊浏览 2025年07月18日 星期五
登录注册

文章基本信息

  • 标题:Aspectos de contaminação biológica em filtros de condicionadores de ar instalados em domicílios da cidade de Manaus - AM
  • 其他标题:Aspects of biological contamination in air conditioning filters installed in Manaus city houses (AM)
  • 本地全文:下载
  • 作者:Cartaxo, Elizabeth Ferreira ; Gonçalves, Ana Catarina Lima Chaves ; Costa, Fabrício Rodrigues
  • 期刊名称:Engenharia Sanitaria e Ambiental
  • 印刷版ISSN:1413-4152
  • 电子版ISSN:1809-4457
  • 出版年度:2007
  • 卷号:12
  • 期号:2
  • 页码:202-211
  • DOI:10.1590/S1413-41522007000200011
  • 语种:Portuguese
  • 出版社:ABES
  • 摘要:

    Este trabalho apresenta resultados da pesquisa de contaminação dos filtros de condicionadores de ar instalados no setor residencial da cidade de Manaus. A pesquisa foi realizada no âmbito do projeto CAEMA (Condicionadores de Ar, Energia e Meio Ambiente) que consistiu na troca de aparelhos de ar condicionado ineficientes por eficientes na zona urbana da cidade. Dos 500 condicionadores de ar retirados do sistema pelo projeto, foram selecionados 50 filtros (10%) para a análise de contaminação biológica, tendo sido identificada uma enorme variedade de agentes prejudiciais à saúde humana, entre bactérias e fungos. A bactéria mais vezes identificada foi a Staphylococcus sp e o fungo mais freqüente foi o Penicillium sp. Também foi possível verificar, por meio de entrevistas telefônicas junto a 37 usuários desses equipamentos, a grande incidência de sintomas associados a problemas de insuficiente qualidade de ar nos ambientes residenciais. Circunstâncias que motivaram a oportunidade desta pesquisa também impossibilitaram a coleta das amostras por unidade de volume, com os condicionadores ainda em funcionamento. Esse fato não comprometeu os objetivos da pesquisa, de promover a reflexão sobre os cuidados com a correta limpeza dos condicionadores de ar residenciais.

  • 其他摘要:

    This work presents the results of a research about the contamination caused by air conditioners filters that are installed in the residential area in Manaus. The research took place in the scope of CAEMA’s project (Conditioning of Air, Energy and Environment), which one consisted in changing inefficient conditional air devices for efficient ones in the urban zone of the city. Amongst 500 air conditioners removed of the system by the project, 50 filters (10%) were selected for biological contamination analysis, having been identified an enormous variety of agents, like bacteria and fungus, that are harmful for human health. The most identified bacterium was the Staphylococcus sp and the fungus more frequent was the Penicillium sp. Also it was possible to verify, by telephonic interviews with 37 users of these equipments, the great incidence of symptoms associates to the insufficient air quality in residential environments. The circumstances that had motivated the chance of this research, had also disabled that the assemble could be made per volume unit, with the conditioners still working. This fact did not compromise the quality of the work, neither the objectives to promote one reflection about the cares with the correct cleanness of the residential air conditioners.

  • 关键词:Contaminação;condicionador de ar;qualidade de ar;fungos e bactérias
  • 其他关键词:Contamination;air conditioning;quality of air;fungus and bacterium
国家哲学社会科学文献中心版权所有